Command/r

esponse table for SIS commands (continued

)

Command

ASCII (T

elnet

)

(host to MLC

)

URL Encoded (W

eb

)

(host to MLC

)

Response

(MLC to host

)

Additional description

Show the absence of or types of connected

devices.

Prefixes for connected devices:

P1 =

SCP

#1, addr

ess 0

P2 =

SCP

#2, addr

ess 1

K1 =

contr

ol module #1, addr

ess 0

K2 =

contr

ol module #2, addr

ess 1

K3 =

contr

ol module #3, addr

ess 2

K4 =

contr

ol module #4, addr

ess 3

S =

MediaLink device, typically a slaved (auxiliary) MLS switcher

.

For :

00 = not pr

esent

01 = MLS 306 02 = MLS 506 03 = MLS 506MA

70 V

04 = MLS 506SA 05 = MLS 506MA

100 V

06 = MLS 100

A

07 = MLS 103 V 08 = MLS 103 SV

09 = MLS 102 VGA 10 = MLA-VC10 11

= MLS 304MA

12 = MLS 406 13 = MLS 406MA 14 = MLS 406SA 15 = MLS 304SA 16 = PVS 204SA 99 = non-MLS, non-

PVS switcher

.

For ##:

00 = not pr

esent

01 = pr

esent (SCP)

or

IRCM-VCR

02 = IRCM-DVD 03 = IRCM DVD+ 04 =

ACM-Level

05 =

ACM-T

one

06 = RCM-SC 07 = RCM-SC

LT

08 = IRCM-T

ape

09 = CM-5BB 10 = CM-20BB 11

= IRCM-DV+

12 = CM-9BLB 13 = CM-3BLB 14 = CM-19AC 99 = unr

ecognized.

000 = not pr

esent

101 = IPI 101

AAP

104 = IPI 104

AAP

For ???:

Examples:

32I

32I

P101 P200 K1

11 K21

1 K307 K408 S09

]

This example includes one SCP

(P101),

an IRCM

-DVD+ (K1

11 and K21

1), an

RCM

-SCL

T (K307), an IRCM

-T

ape (K408),

and an MLS 102 VGA

(S09).

IP setup commands (IP models only

)

Set the unit name

24

E

X1@

C

N

}

W

X1@

CN

|

Ipn•

X1@

]

Change the MLC’s name to one of your

choosing (

X1@

), such as “AuditoriumMLC”,

“Rm316-A

Vcenter”, or “exec-boar

dr

oom-

ctrl”. The name consists of up to 24

alphanumeric characters (and the minus

sign). The first character must be a letter

,

the last character cannot be a minus sign

(hyphen). Either case (upper

, lower) is OK.

Set unit name to factory default

24

E

•CN

}

W%20CN

|

Ipn•

X4(

]

X4(

= the name the MLC was shipped with:

MLC-104-IP-PLUS

-##

-##

-##, a combination

of the model name and the last 3 pairs

of hex numbers in the contr

oller

’s MAC

addr

ess (e.g., MLC-104-IP-PLUS-02-74-62).

Read the unit name

E

CN

}

WCN

|

X1@

]

or

X4(

]

X1@

is the MLC’s curr

ent, user

-defined unit

name.

X4(

is the MLC’s factory default name.

N

The non