Programming and Control, cont’d

MLC 104 Plus Series • SIS Programming and Control

4-36

PRELIMINAR

Y

Command/response table for special function SIS commands, continued

Command

ASCII

Command

(host to MLC)

Response

(MLC to host)

X?

values

and additional descriptions

Each control module (IRCM, ACM, RCM, CM) has 20 memory blocks reserved for it, no matter how many buttons are
physically present on the module:
• module 1: blocks 26-45
• module 2: blocks 46-65

• module 3: blocks 66-85
• module 4: blocks 86-105

N

MLC 104 Plus Series units can be connected to a maximum of four control modules.

See page 2‑12

for cabling

instructions.

Memory block numbers for each module are sequential from left to right, top row to bottom row, as shown below.

SCREEN POSITION

DOWN

UP

STOP

DVD & VCR CONTROL

PLAY NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

DVD & VCR CONTROL

PLAY NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

CM-3BLB

CM-3BLB

CM-9BLB

CM-3BLB, DIP switch set for address 3 (module 4)

Button/Switch Memory Block Numbering for Control Modules (IRCMs, ACMs, RCMs, CMs)

Memory Block Numbering

for Any Control Module

with Black Buttons

(Example is for Control Module 1)

Memory Block Numbering

for Control Modules with

Clear, Backlit Buttons

26 27 28 29 30

26 27 28

35

30

40
45

31

35

34

33

32

36

40

39

38

37

41

45

44

43

42

26 27 28

86 87 88

26 27 28

29 30 31

32 33 34

Memory Block Numbering Examples

for Modules with Black Buttons

DVD Half (module 1)

IRCM-DV+ with DIP switch set for addresses 0 and 1 (modules 1 and 2)

RCM-SC with DIP switch set for address 2 (module 3)

VCR Half (module 2)

31

35

33

32

36

39

29

37

41

45

44

43

42

66

66

68

70

71

76 77 78 79

67

69

82 83 84

80

81

85

72 73 74 75

26

28

30

31

36 37

38

39

27

29

42 43 44

40

41

45

32 33

34

35

70

68

51

55

53

52

56

59

49

57

61

65

64

63

62

Module 3 has
memory blocks 66-85.

Module 1 has
memory blocks 26-45.

46

48

50

51

56 57

58

59

47

49

62 63 64

60

61

65

52 53

54

55

Module 2 has
memory blocks 46-65.

Module 4
has memory
blocks
86-105.

Buttons and memory blocks are
numbered in a grid of 5 columns
and 4 rows of buttons on each
module, as on the CM-20BB,
shown above.

Backlit button modules feature a grid
of 3 columns and 1 or 3 rows of
buttons, as shown at left.

N

There are still 20 memory

blocks for each module.

Module 1: memory blocks 26-45.

Module 2: memory blocks 46-65.

Module 3: memory blocks 66-85.

Module 4: memory blocks 86-105.

CM-3BLB

CM-9BLB

86

87

88

89

90

91

92

93

94

104

105