Preliminar y – Extron Electronics MLC 104 Plus Series User Manual

Page 71

Advertising
background image

4-7

MLC 104 Plus Series • SIS Programming and Control

PRELIMINAR

Y

X6#

= Pulse time in 20 ms increments. If this

parameter is missing or = 0, then pulse

length = default = 25 = 500 ms. 1 =

20 ms (minimum pulse time) to 65535 =

1310700 ms (maximum pulse time).

X6$

= Broadcast repetition interval in seconds

(0 to 255, default = 0 = off)

X6(

= IP connection timeout period specified in

10-second steps (1 - 65000, default =

30 = 300 seconds). If no data is received

during the specified period, the Ethernet

connection closes. Responses are returned

with leading zeros.

X7)

= The number to insert into an email message

if a ____.eml file has an embedded

server-side include “

<!--#echo var =

“WCR

|

” -->” (the

E

CR

}

command

with no parameters.) The numeral is a

16-bit number to be employed as the user

defines.

This is an optional parameter. Use 0 as a
placeholder if the optional

X4&

variable is

used but

X7)

is not needed.

Maximum = 65535.

X7#

= An e-mail account username of up to 31

characters. Do not use commas. This

parameter is optional during setup and is

used for SMTP authentication.

X7$

= An e-mail account password (for SMTP

authentication) of up to 31 characters.

Do not use commas. This parameter is

optional during setup.

X7%

= An optional string for a destination email

address using the form [email protected]

X20)

= Specific input number (1 – 4)

1 = input 1 (the default after a reset)

2 = input 2

3 = input 3

4 = input 4

X20%

= Lamp hours elapsed (0 to 99999 hours)

The five-digit response includes leading

zeros. The default is 99999 hours, which

yields an “N/A” response.

X20^

= Voltage (in volts)

X20&

= Temperature in degrees Celsius (the response

is 3 digits including leading zeros)

X20*

= Display (projector) power status

0 = display power is off (default)

1 = display power is on

2 = display is powering down/off (cooling

down)

3 = display is powering up/on (warming

up)

X20(

= Front panel lockout (executive mode) status

0 = off/unlocked (default)

3 = on, disable/lock entire front panel

(buttons, volume control) and optional

connected SCP, control module(s), and IR

remote control input

X21!

= Status (in hexadecimal characters) of script

or firmware button control

.

This variable

is an 8-digit hexadecimal character

calculated from a binary bit map. It is

case-sensitive. Use capital letters. This

bit mapped number indicates whether

a button is controlled by firmware or by

scripts.

See page 4-29

for details.

X21@

= Status (in hexadecimal characters) of control

of all button lights).

This variable is an 8-digit hexadecimal

character calculated from a binary

bit map, and it is case-sensitive. Use

capital letters. This bit mapped number

indicates whether a button is controlled

by firmware or by scripts.

See page 4-31

for details.

X21%

= IR output port number

1 = projector/display port

X21^

= Display mute or connection status

0 = off/disconnected (default for mute)

1 = on/connected

2 = unknown/unavailable (default for

connection status)

X21&

= Firmware’s event status polling period from

0 to 255 in 20 ms increments.

X21&

is

optional: if it is not set, it defaults to

100 (2 seconds) and is not shown in the
command’s response. If

X21&

is set to 0,

the firmware does not poll for event

status.

N

The event number that is polled is set by

X3%

in

the EN command.

X22#

= Digital I/O port (specifying which port)

1 = digital I/O port 1

2 = digital I/O port 2

3 = digital I/O port 3

Advertising
This manual is related to the following products: