Preliminar y, Programming and control, cont’d – Extron Electronics MLC 104 Plus Series User Manual

Page 74

Advertising
background image

SIS

Programming and Control, cont’d

MLC 104 Plus Series • SIS Programming and Control

4-10

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued

)

Command

ASCII (T

elnet

)

(host to MLC

)

URL Encoded (W

eb

)

(host to MLC

)

Response

(MLC to host

)

Additional description

V

iew the lockout mode status

X

X

X20(]

Show lockout (executive mode) status.

X20(

= 0 (of

f, unlocked) or 3 (fr

ont panels,

contr

ol modules, and r

emote contr

ol

locked/disabled).

Example:

X

X

0

]

Executive mode is of

f.

Status commands

V

iew lamp hours status

6S

6S

X20%]

or

X20%

*

X20%]

X20%

r

epr

esents the number of elapsed

hours of pr

ojector lamp use. The MLC

responds with two sets of lamp hours only

if two lamp hours have been set. If a lamp’s

status has not been set, it is shown as the

default (99999 hours) or “N/A”.

Set lamp hours status for 1 lamp

24

X20%

*6S

X20%

%2A

6S

Lhr*

X20%

]

X20%

repr

esents the five-digit numeric v

alue for elapsed lamp use hours, and it is

used by script to determine the number

sent in r

esponse to the “view lamp hours”

command (6S).

Set lamp hours status for 2

lamps

24

X20%

*

X20%

*6S

X20%

%2A

X20%

%2A

6S

Lhr*

X20%

*

X20%]

V

iew connection status

7S

7S

X21^]

This command lets you know whether

the MLC’s scripts have determined if the

display is still connected to the MLC.

X21^

= 0 (disconnected), 1 (connected), or 2

(unknown).

Set display connection status

24

X21^

*7S

X21^

%2A

7S

Pcs

X21^]

This command is used to r

eset the

pr

ojector/display connection status flag

(

X21^

) used by scripts.

0 = pr

ojector not connected.

1 = pr

ojector is connected.

2 = undetermined status.