Preliminar y, Operation, features, and cabling, cont’d, 1on 2 3 4 – Extron Electronics MLC 104 Plus Series User Manual

Page 30

Advertising
background image

Operation, Features, and Cabling, cont’d

MLC 104 Plus Series • Operation, Features, and Cabling

2-14

PRELIMINAR

Y

MLC 104 IP Plus DV+ connections

:

The MLC 104 IP Plus DV+ consists of an MLC 104 IP Plus controller and an

IRCM-DV+ installed in a high-impact plastic faceplate. The wiring is the same as in

the previous diagram, except the

IRCM-DV+ is cabled to the MLC at the

factory, as shown in the following

diagram.

An MLC 104 IP Plus DV+ with SCPs and additional control modules

c

Digital I/O ports — The Digital I/O area (shown at right) provides

three ports that can be configured as digital inputs or outputs,

with or without +5 VDC pull-up. Connecting these ports to

sensors, switches, LEDs, or relays allows for a way to trigger

events or functions (such as triggering relays, issuing commands,

or sending an e-mail) that have been configured using Global

Configurator (GC) software.

C

Configure these ports using Global Configurator software or SIS commands

first, and then connect wires the MLC’s ports. A mismatch between port
configuration and wiring can cause malfunctions or unit failure.

Digital input

— To allow the MLC to monitor devices such as push buttons,

connect a switch, motion sensor, moisture sensor, tally feedback output, or a

similar item to a digital input port. When one of these ports is configured as

a digital input, it is set to measure two states: high and low. The port accepts

0 to 12 VDC input. The threshold voltages are as follows: a voltage below

2.0 VDC is measured as logic low, and a voltage above 2.8 VDC is measured

as logic high. There is also an internal, +5 VDC, selectable, pull-up resistor for

this circuit.

MLC 104 IP Plus DV+ Rear Panel

A

D

B

C

E

A

D

B

C

E

RUN

100

A

D

B C

E

A

D

B C

E

1

ON

2
3
4

J1

SCP 104 Rear Panel

IRCM-DV+
Rear Panel

A

D

B C

E

A

D

B C

E

1

ON

2
3
4

J1

SCP 104 Rear Panel

IRCM-DV+
Rear Panel

Factory-wired
MLC - to - IRCM-DV+
Connection

Right

Side Panel

2

3

G

R

O

U

N

D

1

DIGITAL

I/O