Preliminar y, Programming and control, cont’d – Extron Electronics MLC 104 Plus Series User Manual

Page 78

Advertising
background image

SIS

Programming and Control, cont’d

MLC 104 Plus Series • SIS Programming and Control

4-14

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued

)

Command

ASCII (T

elnet

)

(host to MLC

)

URL Encoded (W

eb

)

(host to MLC

)

Response

(MLC to host

)

Additional description

IR/serial data port

Send an IR command

28

E

X21%

,

X5&

,

X5*

,

X5(

IR

}

Send an IR command via IR/Serial Output

port number

X21%

(1 = display port).

X5&

= the IR file number (0-99),

X5*

= IR

function number (1-137),

X5(

= IR playback

mode (0 = play once, 1 = play continuously

,

2 = stop). The r

esponse includes leading

zer

os.

W

X21%

%2C

X5&

%2C

X5*

%2C

X5(

IR

|

Irs

X21%

,

X5&

,

X5*

,

X5(

]

Get IR command info

13, 28

E

X5&

,

X5*

IR

}

W

X5&

%2C

X5*

IR

|

{descriptive text}

]

The r

esponse to this command is the name/

description (e.g., Power On, Power Of

f,

Enter

, Play

, Stop, RGB, Menu) of the specific

command you ask about.

X5&

= the IR file number (0-99), as in files

1.eir

, 2.eir

, 3.eir

, etc. stor

ed in the contr

oller

.

Each

___.eir

file

contains

commands

for

a

specific device.

X5*

= IR playback function number (1-137),

which corr

esponds to a specific function/

command set contained within the file. IR

function numbers 0 and 127 or higher can

return information only

.

0 = r

eturn all data

129 = manufactur

er

130 = model

131 = class

132 = r

emote

133 = cr

eation date

134 = comments

137 = user file name (a descriptive name the

user/installer gave the file)

Example:

E

3,1IR

}

W3%2C1IR

|

POWER

]

Command/function 1 in file

3.eir

is the

Power command.

Example:

E

3,2IR

}

W3%2C2IR

|

E13

]

Command/function 2 in file

3.eir

is not

defined or does not exist, so the contr

oller

returns E13, the invalid value err

or number

.

N

An IR driver must be loaded into the MLC befor

e IR command information can be r

ead.

Advertising