Firmware Updates, cont’d

MLC 104 Plus Series • Firmware Updates

B-6

PRELIMINAR

Y

b.

For serial communication, select RS-232 and set the communications

settings to 38400 baud, no parity, 8 data bits, 1 stop bit.

4.

Click the OK button. A window like

the one shown at right appears. It

shows the firmware version currently

used by the MLC.

5.

Type in the filename and path of the

new firmware file or click the Browse

button to view folders to find the file.

If you click Browse, the Choose

Firmware File window (shown below)

appears. Locate and select the

firmware file, and click the Open

button.

6.

Click Upload in the Firmware Loader

window. The PC uploads the new

firmware into the MLC. Once the

firmware is uploaded, the MLC resets

itself and the front panel lights blink as

they do during power-on. The

Firmware Loader software displays the

new firmware version, as shown at

right.

7.

Click Exit in that window, and

click Exit in the Firmware Loader

connections window.

8.

Follow the instructions in “Resetting

the MLC and restoring its configuration” later in this chapter.