MLC 104 Plus Series • Special Applications

PRELIMINAR

Y

5.

If you want to use the MLC’s buttons to control Extron switcher inputs other

than the default inputs 1-4, remap the front panel buttons.
a.

Click the Front Panel tab.

b.

Click an input button.

c.

Select the desired switcher input number from the Switcher Input list

box. In the example shown above, a document camera is connected to

input 12 of the switcher.

d.

Repeat steps 5b and 5c as desired to remap additional buttons to other

switcher inputs.

6.

Complete the rest of the configuration as desired, then save the project and

build and upload the configuration to the MLC.

Using Digital Inputs

The MLC can monitor devices such as push buttons, switches, a motion sensor,

moisture sensor, tally feedback output, or a similar item via a digital input port.

When one of these ports is configured as a digital input, it is set to measure two

states: high and low. The port accepts 0 to 12 VDC input. The threshold voltages

are as follows: a voltage below 2.0 VDC is measured as logic low, and a voltage

above 2.8 VDC is measured as logic high. There is also an internal, 2k ohm,

+5 VDC, selectable, pull-up resistor for this circuit for contact closure detection.
The following examples tell how you can use these pins for digital input.

Using a motorized surface access enclosure to trigger digital

input

One application for digital input on the MLC is monitoring the up/open and

down/closed status of an Extron HSA 822M motorized surface access enclosure to

signal when to power on or power off a projector or display.

1.

In the Advanced Configuration tab in the Global Configurator software,

configure the MLC’s digital I/O ports (ports 2

and 3 in this example) for digital input with pull-

up, as shown at right.

2.

Set up a monitor for each port in the Monitor tab

of Global Configurator.
a.

Click the Monitor tab (

), then

click Add Monitor (near the bottom of the GC window). The Monitor

Conditions Wizard window appears.

b.

Type in the name of the first monitored condition: HSA in up position.