MLC 104 Plus Series • Special Applications

5-20

PRELIMINAR

Y

5.

Power on the equipment, and test the system. When one button is pressed, it

makes momentary contact, completing the circuit with MLC digital input 1.

The MLC’s monitor detects the change and sends out the safety alert e-mail

to the safety office. When the other button is pressed, it briefly completes the

circuit with digital input 2, triggering the MLC to issue the administration

office e-mail alert.

6.

Make any needed changes and complete the installation.

Using Digital Outputs

To power devices that accept a TTL signal or to provide contact closure control for

projector lifts, motorized screens, room or light switches via an Extron IPA T RLY4,

you can use one or more of the MLC’s digital I/O ports configured for digital

output. When the port is set to an “on” state, (the circuit is closed), the I/O pin is

connected to ground. Each I/O port is capable of accepting 250 mA, maximum.

When the port is set to the “off” state (the circuit is open), the output pin is floating.

If the application calls for TTL compatibility, the digital output circuit can be set up

to provide a 2k ohm pull-up resistor to +5 VDC.

Controlling a Low Voltage Screen Motor Controller

The MLC 104 Plus Series does not have built-in relays that can be connected

directly to a low voltage screen controller. However, with the addition of an Extron

IPA T RLY4 relay controller and a few configuration steps, you can still raise or

lower a projection screen using the MLC, a screen controller, and a screen control

motor.
Follow the procedures in this section to cable the devices and then configure the

MLC for this application.

Cabling the equipment

1.

Connect the MLC to an IPA T RLY4 ‘s front panel inputs as shown below.

The MLC

provides

12 VDC to the

IPA’s common

voltage pin (C).

Each MLC

digital I/O

port (1, 2, 3)

connects

to the

corresponding

relay input

pin (1, 2, 3) on

the IPA.

N

Extron Comm‑Link cable (CTL, part #22‑148‑02/‑03; or CTLP, part

#22‑119‑02/‑03) can be used for these connections.

2.

Connect the IPA T RLY4’s rear panel relay ports to the low voltage screen

controller. The following illustrations provide examples of how to wire

the IPA T RLY4 to typical low voltage screen controllers. However, your

1
2
3

GROUND

+12V OUT

CM

GROUND

IR OUT

GROUND

SCP

GROUND

Tx
Rx

DISPLA

Y

RS-232/IR

A B C D E

COMM LINK

LAN

PRESS

TAB
WITH

TWEEKER

TO REMO

VE

A B

MLS

RS-232

PO

WER

12V

DIGIT

AL

I/O

IR IN

Tx

GROUND

Rx

+12V IN

IP

A

T RL

Y4

1 2 3 4

C

INPUTS

MLC 104 Plus Series
Right Side

IPA T RLY4
Front Panel

Relay 1

Relay 2

Relay 3

+12 VDC