Specifications — MLC 104 Plus

Control — host ports

Serial host port ............................... 1 bidirectional RS-232 front panel 2.5 mm mini stereo jack
Baud rate and protocol ................. 38400, 8 data bits, 1 stop bit, no parity
Serial control pin configurations . Mini stereo jack: tip = TX, ring = RX, sleeve = GND
Secondary control panel (SCP) .... (1) 3.5 mm 5-pole direct insertion captive screw connector
Program control ............................. Extron's Global Configurator for Windows

®

, version 2.5 or later

Extron's Simple Instruction Set (SIS

)

IR learning frequencies ................. 30 kHz to 62 kHz
IR learning distance ...................... 2" (5.1 cm) to 12" (30.5 cm) from the top panel

Control — serial ports

Display control port ...................... (1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional

RS-232 control (± 5V)

Switcher control port .................... (1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional

RS-232 control (±5 V)

Baud rate and protocol (RS-232) . 115200 to 300 baud (9600 baud = default); 8 (default) or 7 data bits; 1(default)

or 2 stop bits; no parity (default), or even or odd parity

Control — IR port

IR control port ................................ (1) 3.5 mm direct insertion captive screw connector, 2 pole

TTL level (0 to 5 V) infrared control up to 1 MHz

Digital I/O control

Number/type ................................ 3 digital input/output (configurable)
Connector ....................................... (1) 3.5 mm direct insertion captive screw connector, 4 pole
Pin configuration ........................... 1, 2, 3 = digital inputs/outputs 1, 2, and 3; GND = GND
Digital inputs

Input voltage range ........... 0-12 VDC
Input impedance ............... 28k ohms
Programmable pullup ...... 2k ohms to +5 VDC
Threshold low to high ...... >2.8 VDC
Threshold high to low ...... <2.0 VDC

Digital outputs ............................... 250 mA sink from 24 VDC, maximum

General

External power supply ................. 100 VAC to 240 VAC, 50/60 Hz, external; to 12 VDC, 1 A, regulated
Power input requirements ........... 12 VDC, 0.285 A (0.305 A if used with an optional IRCM-DV+)

N

An MLC 104 Plus controller must be powered by its own power supply. It cannot be powered by an
MLS switcher.

Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling ........................................... Convection, unvented
Mounting

Rack mount ........................ Yes, with optional rack mounting kits
Wall mount ......................... Yes, wall- and furniture-mountable with optional mounting kits

Enclosure type ............................... Metal faceplate, metal rear enclosure