Page 172: Preliminar y, Firmware updates

Advertising
background image

MLC 104 Plus Series • Firmware Updates

B-2

Firmware Updates

PRELIMINAR

Y

If the need arises, you can replace the Extron MLC controller’s main firmware

without opening the unit or changing firmware chips.

Determining the Firmware Version

There are several ways to check which version of firmware the controller is using:
• the IP Link Settings tab within Extron Global Configurator software
• the System Status or the System Settings page of the controller’s embedded Web

pages (for IP models)

• the Info page of GlobalViewer

®

Web pages (if installed on an IP model controller)

• the Version column within Extron IP Link

®

Device Manager software

• the response from the MLC to an SIS command of 1Q or 0Q (See chapter 5.)

Using the Global Configurator software

1.

Via RS-232 or Ethernet, connect a PC (on which the Global Configurator

program has been installed) to the MLC.

2.

Start the Global Configurator (GC) program and open a project. (See the

MLC 104 Plus Series Setup Guide

and chapter 4 of this manual for details.)

3.

In the window on the left side of the GC screen, click on the name of the MLC

for which you want to check the firmware level.

4.

In the right side of the GC screen, click the IP Link Settings tab.

5.

Click the Refresh button. The firmware version is listed in the System

Description area.

Using a Web browser (IP models only)

The controller comes with a set of factory default embedded Web pages. Also, if

the MLC controller is used as part of a network of devices based on Extron IP Link

®

technology, such as IP Link interfaces, the GlobalViewer application could be

installed in the MLC as well as in other IP Link devices within the network. Refer

to the Global Configurator help file for information on how to use that software and

the resulting Web pages.

1.

Connect the controller to a PC via an Ethernet connection, or connect the

controller and the PC to a network/LAN. See chapters 2 and 4 of this manual

and read the MLC 104 Plus Series Setup Guide for details.

2.

Start a Web browser program (such as Microsoft

®

Internet Explorer

®

or

Netscape

®

Navigator

®

).

3.

Type the MLC’s IP address into the browser’s address area and log on to the

MLC’s internal Web page (see chapter 4) or to the optional GlobalViewer Web

page stored in the MLC. (See the Global Configurator help file for details.)

N

If GlobalViewer is installed in the MLC, the GlobalViewer Web pages appear by

default.
• GlobalViewer Web pages are supported by Internet Explorer, but not by other

browsers. GlobalViewer features may not work properly when viewed via
Navigator, Mozilla

®

Firefox

®

, or other browser programs.

• To reach the factory default Web pages on a controller that has been set

up for GlobalViewer, type http://<IP address>/nortxe_index.html into
the browser’s address area, substituting the unit’s actual IP address for
“<IP address>”. For example,

http://10.13.196.42/nortxe_index.html.

Advertising