Resetting the MLC and restoring its configuration

After a firmware update you must reset the unit. Resetting the MLC also removes

configuration information, so replace the MLC’s configuration after resetting.

1.

Perform a ZY reset, which is an absolute system reset excluding IP settings (IP

address, subnet mask, gateway IP address, unit name, DHCP settings, port

mapping). This allows you to maintain communication with the MLC.

If using Telnet or HyperTerminal, enter

E

ZY

}

.

If using a Web browser connection, enter W ZY

|

.

2.

Using Global Configurator, restore (build) the previously saved project to the

MLC.