Operation, Features, and Cabling, cont’d

MLC 104 Plus Series • Operation, Features, and Cabling

2-6

PRELIMINAR

Y

Front Panel Security Lockout (Executive Mode)

To prevent accidental changes to settings, the MLC features front panel security

lockout (executive) modes for disabling access to controls. When front panel

lockout is enabled, if a button is pressed, the button flashes red, but no change

occurs. Nothing—not input switching, projector control, room control, volume

adjustment, or any other knob- or button-executable function—results from front

panel actions when lockout is active. Button and knob functions on the IR 402

remote control, SCPs, or control modules are also locked. Changes can still be

made via RS-232 or, for IP models, via Ethernet (Telnet or Web browser) control.
The SIS command 3X corresponds to and also enables this mode (

see page 4 -10

).

For details, see chapters 3 and 4. The only way to override a front panel lockout

via the front panel is to enter a personal identification number (PIN) to unlock the

panel, using the MLC’s input buttons as a numeric keypad for PIN entry, as shown

on

page 2-7

.

Enabling and disabling front panel lockout via the embedded Web pages

and the front panel

Front panel lockout can be enabled/disabled using the embedded Web pages

whether or not a PIN has been set. However, a PIN must be set up before you can

enable or disable lockout using the front panel buttons.

Using the Web pages (IP models)

1.

Using a Web browser, enter the MLC’s IP address to open the MLC’s

embedded Web page. If an administrator password has been set and if you

are prompted to do so, type in the administrator password.

2.

Click on the Configuration tab, which opens to the System Settings page.

3.

Select either Off or Disable Front Panel, SCP, Control Modules and IR in the

Executive Mode settings area. See the following picture.

N

If Disable Front Panel, SCP, Control Modules and IR is selected via the

System Settings factory default Web page, front panel lockout can’t be enabled/
disabled via the front panel unless PIN Mode is enabled.

See page 4‑40

to find

the SIS commands for PIN enabling/disabling.