Resetting the Unit

There are four reset modes (numbered 1, 3, 4, and 5 for the sake of comparison

with an Extron IPL product) that are available by pressing the Reset button on the

side panel. The Reset button is recessed, so use a pointed stylus, ballpoint pen, or

Extron Tweeker to access it. See the following table for a summary of the modes.

C

Review the reset modes carefully. Using the wrong reset mode may result

in unintended loss of flash memory programming, port reassignment, or a
controller reboot.

N

The reset modes listed below close all open IP and Telnet connections and close

all sockets. The following modes are separate functions, not a continuation from
Mode 1 to Mode 5. Also, IP settings do not apply to the MLC 104 Plus.

The MLC reverts to the factory default
firmware.

Event scripting will not start if

the MLC is powered on in this mode. All

user files and settings (drivers,

adjustments, IP settings, etc.) are

maintained.

If you do not want to update
firmware, or you performed a mode 1 reset
by mistake, cycle power to the MLC to
return to the firmware version that was
running prior to the mode 1 reset. Use the
0Q SIS command to confirm that the
factory default firmware is no longer
running (look for asterisks following the
version number.)

Mode 3 turns events on or off.

During

resetting, the Reset LED flashes 2 times if

events are starting, 3 times if events are

stopping.

Mode 4
• Enables ARP capability.

• Sets the IP address back to factory

default.

• Sets the subnet back to factory default.

• Sets the default gateway address back

to the factory default.

• Sets port mapping back to factory

default.

• Turns DHCP off.

• Turns events off.

The Reset LED flashes 4 times in quick

succession during reset.

Mode 5 performs a complete reset to
factory defaults (except the firmware).
• Does everything mode 4 does.

• Resets almost all the real time

adjustments: all audio settings, limit

initial power up volume, power

up/down delay, auto power down, and

misc. options. This does not affect an

optional MLS switcher, however.

• Clears driver-port associations and port

configurations (IR/RS-232).

• Removes button configurations.

• Resets all IP options.

• Removes scheduling settings.

• Removes/clears all files from switcher.

The Reset LED flashes 4 times in quick

succession during the reset.

Reset Mode Comparison/Summary

Mode Activation

Result

Purpose/Notes

1

Hold down the recessed

Reset button while applying

power to the MLC.

After a mode 1 reset

is performed, update the
MLC’s firmware to the latest
version. Do not operate the
MLC firmware version that
results from the mode 1
reset. If you want to use the
factory default firmware, you
must upload that version
again. See appendix B,
“Firmware Updates,” for
details on uploading
firmware.

3

Hold down the Reset button

for about 3 sec. until the Reset

LED blinks once, then release

and press Reset momentarily

(<1 sec.) within 1 second.

4

Hold down the Reset button

for about 6 sec. until the

Reset LED has blinked twice

(once at 3 sec., again at 6 sec.).

Then release and press Reset

momentarily (for <1 sec.)

within 1 second.

5

Hold down the Reset button

for about 9 sec. until the

Reset LED has blinked three

times (once at 3 sec., again at

6 sec., again at 9 sec.). Then

release and press Reset

momentarily (for <1 sec.)

within 1 second.

Use mode 1 to revert

to the factory default

firmware version if

incompatibility issues

arise with

user-loaded firmware.

Mode 3 is useful for

troubleshooting.

Mode 4 enables you

to set IP address

information using

ARP and the MAC

address.

Mode 5 is useful if

you want to start over

with configuration

and uploading, and

also to replace events.