Preliminar y – Extron Electronics MLC 104 Plus Series User Manual

Page 45

Advertising
background image

3-5

MLC 104 Plus Series • Software-based Configuration and Control

PRELIMINAR

Y

5.

Execute a ping command by entering “ping” followed by a space and the new

IP address at the command prompt. For example:

ping 10.13.197.9

You must ping the MLC in order for the IP address change to take place.

The response should show the controller’s new IP address, as shown in the

following picture.

You can reconnect using either Telnet or a Web browser to verify that the

update was successful.

6.

After verifying that the IP address change was successful, enter and issue the

arp –d

command at the DOS prompt. For example:

arp –d 10.13.197.9

removes 10.13.197.9 from the ARP table

or

arp –d*

removes all static IP addresses from the ARP table.

Configuring the MLC 104 IP Plus for network communication

via a Web browser

The default Web pages that are preloaded on the MLC 104 IP Plus are compatible

with popular Web browsers such as Netscape Navigator (version 6.0 or higher),

Microsoft Internet Explorer (version 5.5 or higher), or Mozilla Firefox (version 1.0

or higher). However, the MLC and the PC must both be part of the same subnet

before they can communicate via the LAN port. You must change the PC’s IP

address to one that is on the same subnet as the default IP address of the MLC

(192.168.254.254).

N

This method requires a crossover cable.

See page 2‑9

for cabling details.

N

Make a note of the host PC's TCP/IP configuration before changing its IP

address and make sure the PC and MLC are on the same subnet.

1.

Temporarily change the host PC’s IP address.

See “Setting up the PC for IP

communication with an IP-enabled MLC”

later in this chapter for step-by-step

instructions.

2.

Obtain a valid IP address for the controller from your network administrator.

3.

Launch the Web browser on the connected PC (for which you set up the

network configuration earlier), and enter “http://192.168.254.254/” in the

address box. The MLC’s default Web page is displayed.