GC processes the information about the selected device(s), generates a document

containing the wiring diagram, and opens that document in Word. Print the

diagram(s), save the file, if desired, and exit Word. Close the Global Configurator

Print Wiring Diagrams window.

Updating firmware

If the need arises, you can replace the MLC’s firmware without opening the unit or

changing firmware chips. See

appendix B, “Firmware Updates”

, for instructions on

how to update the controller’s firmware.

N

Save the existing configuration project before replacing the firmware.

Saving and uploading the configuration

This is not an advanced configuration function, but when you finish creating the

configuration in Global Configurator, you must save the GC project and upload the

configuration to one or more MLC units. See chapter 3 of the MLC 104 Plus Series

Setup Guide

(shipped with the MLC) for instructions.

Controlling an IP Link-enabled MLC

You can control the MLC 104 IP Plus and devices connected to it by using the

MLC’s factory-embedded Web pages or its GlobalViewer (GV) Web pages that were

created when you uploaded the GC configuration or a customized graphical user

interface (GUI).

Embedded Web pages

The MLC 104 IP Plus features an embedded Web server, which includes factory-

set Web pages. These pages can be replaced with user-designed files, but the

default Web pages provide many basic features for monitoring, configuring, and

controlling the MLC via a Web browser. These Web pages provide some of the

features of the configuration program. This section provides an overview of the

embedded Web pages.
To access the embedded Web pages,

1.

Launch a Web browser (Internet Explorer, Netscape Navigator, Mozilla

Firefox) on the connected PC, and enter the MLC’s IP address in the address

field.

2.

In the Connect to <IP address> dialog

box, shown at right, enter the MLC’s IP

address or text of your choice in the User

Name field, type in the administrator

password in the Password field, and click
OK

. The MLC 104 IP Plus’s default Web

page appears.

N

If the MLC has not already been

configured with a password, this
password dialog box does not appear; the
default Web page opens directly.

N

Passwords must contain 4 to 12 alphanumeric characters. Symbols and spaces

are not allowed, and the passwords are case sensitive.

N

Administrators have access to all of the Web pages and are able to make

changes to settings. Users can access the System Status and Control: User
Mode

pages only.