Command/response table for sis commands, Command/response table for sis commands -8, Preliminar y – Extron Electronics MLC 104 Plus Series User Manual

Page 72: Programming and control, cont’d, Command/r esponse table for sis commands

Advertising
background image

SIS

Programming and Control, cont’d

MLC 104 Plus Series • SIS Programming and Control

4-8

PRELIMINAR

Y

Command

ASCII (T

elnet

)

(host to MLC

)

URL Encoded (W

eb

)

(host to MLC

)

Response

(MLC to host

)

Additional description

Input selection

Select an input

14, 22

X20)

!

X20)

%21

Chn

X20)

]

Select input

X20)

(

X20)

= 1, 2, 3, 4) (audio

and video).

14

= The MLC r

esponds with an E14 err

or

code (invalid for this configuration) if the

desir

ed input is not set up to switch inputs

(is not in input button mode). Events ar

e

still trigger

ed, though.

22

= The MLC sends a “busy” r

esponse (E22)

if switching functions ar

e locked.

Display (pr

ojector

) power

Turn display power on

1P

1P

Pwr

X20*]

On (discr

ete).

Turn display power of

f

0P

0P

Pwr

X20*]

Of

f (discr

ete).

V

iew display power status

P

P

X20*]

Show the display power status.

Example:

P

P

2

]

Example:

the display is powering of

f.

Set power status

X20*

*0P

X20*

%2A0P

Pwr

X20*]

This command is used only by scripts. It

pr

ovides a way to set the power status to

match the actual state of the pr

ojector

.

For

X20*

:

0 = display power is of

f

1 = display power is on (default)

2 = display is powering down/of

f

3 = display is powering on (warming up).

N

This command does not trigger the warm up/cool down (power on/power off) sequences or the button’

s events.

Display mute

N

The 1M and 0M commands emulate the IR 402’

s Display Mute On and Display Mute Off buttons. Y

ou must pr

ogram these buttons on the r

emote for the 1M and 0M

commands to function.

Turn display mute on

1M

1M

Mut

X21^]

Mute.

X21^

= 0 (of

f), 1 (on),

or 2 (unknown).

Turn display mute of

f

0M

0M

Mut

X21^]

Unmute.

V

iew display mute status

M

M

X21^]

Show display mute status.

Set mute status

X21^

*0M

X21^

%2A0M

Mut

X21^

]

This command is used only by scripts. It

pr

ovides a way to set the status to match the

actual state of the pr

ojector

.

N

This command does not trigger button events.

Command/r

esponse table for SIS commands