4-33

MLC 104 Plus Series • SIS Programming and Control

PRELIMINAR

Y

The syntax for setting a special function for an MLC is

X?

* __ # where

X?

is the

value and __ is the function number. To view a function’s setting, use __#,

where __ is the function number. In the following table the values of the

X?

variable

are different for each command/function. These values are given in the rightmost

column.

Command/response table for special function SIS commands

(accessible via RS-232 only)

Command

ASCII

Command

(host to MLC)

Response

(MLC to host)

X?

values

and additional descriptions

Delay times

Most projectors require a certain amount of time during warm-up and cool-down during which they do not accept
commands. Set the “lock input selection during power on/off” command (53#,

page 4-39

) first. Then send this

command (1#) to specify the amount of time for the MLC to wait between sending the projector a power-on or
power-off command and when the next input button press can occur.

N

Global Configurator automatically sets the warm‑up and cool‑down delay times based on default values in the display/

projector’s driver. This SIS command overrides the default settings. For best results, set delay times to 2 to 4 seconds
longer than the times required by the display/projector. This ensures that the correct Display power button state is
shown on the front panel and on the GV and standard embedded Web pages.

Power on delay

24

X?

*1#

WarmUp*

X?]

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).

Example:

8*1#

WarmUp*008

Example:

set a 16 second power

on delay.

Example:

1#

023

Example:

view the power on

delay setting (23 = 46 seconds).

Power off delay

24

X?

*2#

CoolDown*

X? ]

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,... in 2 second
steps up to 150 = 300 seconds.

Example:

23*2#

CoolDown*023

]

Example:

set a 46 second power

off delay.

Power off button delay

24

X?

*22#

PwrOffDly*

X? ]

0 = the power off button
requires no hold delay (default),
1 = the power off button
requires a 2-second hold delay
before starting the power-off
sequence.

Audio settings

Limit audio level on display
power-on

24

X?

*11#

VolLimit*

X? ]

If this feature is enabled, the
maximum initial power-up
volume level does not exceed
the level specified by this
command.
0 = audio off, ...,
20 = default value, ...,
100 = no limit on audio level at
power-on.

N

The maximum is limited by the maximum volume setting (47#). If the maximum volume (47# command) is set, the

limit audio level feature (11# command) is automatically set to 25% of the maximum volume (47#).

See page 4‑39

.