PD865 Snooper Modbus

Serial Input Meter

Instruction Manual

21

4-20 mA Output Connections
Connections for the 4-20 mA transmitter output are made to the
connector terminals labeled “mA OUT, I-, I+”. The 4-20 mA output may
be powered from an internal power supply (optional) or from an external
power supply.

Remote Display,

Chart Recorder,

etc.

+

-

P+

2

1

P-

24V OUT

1

2

mA OUT RLY2 RLY1

3

4

5

6

I-

I+

NO

COM

NO

COM

Figure 10: 4-20 mA Output Powered by Meter

Remote Display,

Chart Recorder,

etc.

+

-

External

Power

Supply

+

-

1

2

mA OUT RLY2 RLY1

3

4

5

6

I-

I+

NO

COM

NO

COM

Figure 11: 4-20 mA Output Powered Externally