To Set the Amplitude Parameters

Amplitude

Set the RF output amplitude.


Press LEVELLevel, use the numeric keyboard to input the amplitude value and
select the desired unit from the pop-up unit menu or unit keys.
 The amplitude units available are dBm, -dBm, mV, μV and nV.
 Press Enter to select the default unit (dBm).
 You can also press the left/right direction keys to enter the parameter editing

state and move the cursor to the specified digit and then use the up/down

direction keys or knob to modify the value.

 You can also use the up/down direction keys or knob to modify the amplitude at

the current step.

 Press LEVELLevel and then press Step to set the step.

Amplitude Limit

Set the limit of the RF output amplitude. This value is the upper limit of the RF output

amplitude.

To limit the output amplitude, you can use the amplitude limit function to avoid

damage caused by delivering a high powered signal to the external circuit.


Press LEVELLimit, use the numeric keyboard to input the value of the amplitude
limit and select the desired unit from the pop-up unit menu or unit keys.
 The amplitude limit units available are dBm, -dBm, mV, μV and nV.
 Press Enter to select the default unit (dBm).
 You can also press the left/right direction keys to enter the parameter editing

state and move the cursor to the specified digit; and then use the up/down

direction keys or knob to modify the value.

 You can also use the up/down direction keys or knob to modify the amplitude

limit at the current step.

 Press LEVELLimit and then press Step to set the step.