Network id, Splash screen, Front panel led – Rosen Aviation 1702 Series : 17.5 inch WideScreen High definition User Manual
Page 25: Source mode
Rosen Aviation
17.5” HD Widescreen Display
Document Number: 102990
Revision: C
Date: 03/17/14
Template: 4.2.3-6-FM; Revision A; 16 May, 2005
Page 25 of 34
8.4. Network ID
Use this option to specify the IR and RS-485 network addresses to control multiple displays from
a single cabin management system or remote control.
Each display requires a unique address on the RS-485 network. Setting this address sets the
value for both interfaces. Network settings for Rosen displays are scaled from 1 to 31.
From the Technician Menu, press the
▼ button to select the Network ID, and then press
ENTER to open the screen.
Use the
▲▼ buttons to select an address between 1 and 31 for the display and press ENTER.
Press EXIT to exit the OSD.
8.5. Splash Screen
Use this option to turn a pre-configured splash screen on or off. The splash screen appears for
approximately eight seconds when 28V power is first applied to the display.
When enabled, the Rosen Aviation splash screen appears. When disabled, the screen remains
black.
Highlight TechnicianSplash Screen and press ENTER.
Use the
▲▼ buttons to set the option and then press ENTER.
Press EXIT to exit the OSD.
8.6. Front Panel LED
The Front Panel LED option turns the IR window LED on or off. When the option is Off, the LED
will be black. When it is On, the LED will have the following states:
Green indicates the display is receiving power.
Amber indicates the display is in standby mode.
Red indicates the display is registering an error.
Black indicates the display is receiving no power.
Highlight TechnicianFront Panel LED and press ENTER.
Use the
▲▼ buttons to set the option and then press ENTER.
Press EXIT to exit the OSD.
8.7. Source Mode
This submenu enables you to set the Source Select mode to a specific state: either Momentary
Switch Mode, or Constant Switch Mode.
Highlight TechnicianSource Mode and press ENTER.
Use the
▲▼ buttons to set the option and then press ENTER.
Note: To ensure proper operation, perform a power cycle after changing a setting.