Msi enable/disable msi check character calculation, Default, Msi enable/disable – Datalogic QuickScan Lite QW2100 User Manual

Page 223: Msi check character calculation

Advertising
background image

MSI

Product Reference Guide

213

ENTER/EXIT PROGRAMMING MODE

MSI

The following options apply to the MSI symbology.

MSI Enable/Disable

Enables/Disables ability of reader to decode MSI labels.

MSI Check Character Calculation

Enables/Disables calculation and verification of an optional MSI check character.

$CMSEN00

MSI = Disable

$CMSEN01

MSI = Enable

DEFAULT

$CMSCC00

MSI Check Character Calculation = Disable

$CMSCC01

MSI Check Character Calculation = Enable Mod10

$CMSCC02

MSI Check Character Calculation = Enable Mod11/10

$CMSCC03

MSI Check Character Calculation = Enable Mod10/10

DEFAULT

Advertising