Ack character – Datalogic QuickScan Lite QW2100 User Manual

Page 261

Advertising
background image

ACK Character

Product Reference Guide

251

ACK Character

This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII
characters or any hex value from 0 to 0xFF can be selected.

To set this feature:

1. Determine the desired character or value.

2. Use the

ASCII Chart

on the inside back cover of this manual to find the hex equivalent

for the desired character/value.

3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

4. Scan the bar code: SELECT ACK CHARACTER SETTING.

5. Scan the appropriate two alpha-numeric characters from the keypad in

Appendix E,

Keypad

, that represent the desired character/value in step

1

above. The second character

will cause a two-beep indication.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 8

for some examples of how to set this feature.

Table 8. ACK Character Setting Examples

NOTE

Setting to previously defined characters such as XON, XOFF,
or host commands conflicts with normal operation of these
characters. 8-bit data is not recognized when the option

Data

Bits

has been set as 7 Data Bits.

STEP

ACTION

EXAMPLES

1

Desired Character/Value

ACK

$

@

>

2

Hex equivalent

0x06

0x24

0x40

0x3E

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK CHARACTER SETTING

5

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘6’

‘2’ and ‘4’

‘4’ and ‘0’

‘3’ AND ‘E’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising