Set length 1, For mor, Set length 1 on – Datalogic QuickScan Lite QW2100 User Manual

Page 278

Advertising
background image

References

268

QuickScan

TM

Lite QW2100

Set Length 1

This feature specifies one of the bar code lengths for a given symbology. Length 1 is the mini-
mum label length if in Varible Length Mode, or the first fixed length if in Fixed Length Mode.
Length includes the bar code’s data characters only.

Reference the

Symbologies

section to view the selectable range (number of characters) for the

symbology being set.

Follow these instructions to set this feature:

1. Determine the desired character length. Pad the number with leading zeroes to yield two

digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

3. Scan the “Select Length 1 Setting” for the symbology being set.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent

the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.

5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 2

for some examples of how to set this feature.

Table 19. Length 1 Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

52 Characters

74 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT LENGTH 1SETTING for the desired symbology

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘1’

‘0’ and ‘7’

‘5’ and ‘2’

‘7’ AND ‘4’

5

Scan ENTER/EXIT PROGRAMMING MODE

Advertising