Disable character, Disable character on – Datalogic QuickScan Lite QW2100 User Manual

Page 265

Advertising
background image

Disable Character

Product Reference Guide

255

Disable Character

Specifies the value of the RS-232 host command used to disable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected.

To set the value:

1. Determine the desired character or value. A setting of 0xFF indicates the the Disable

Character is not used (not available).

2. Use the

ASCII Chart

on the inside back cover of this manual to find the hex equivalent

for the desired character/value.

3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

4. Scan the bar code: SELECT DISABLE CHARACTER SETTING.

5. Scan the appropriate two alpha-numeric characters from the keypad in

Appendix E,

Keypad

, that represent the desired character/value in step

1

above. The second character

will cause a two-beep indication.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 12

for some examples of how to set this feature.

Table 12. Disable Character Setting Examples

NOTE

Setting to previously defined characters such as XON, XOFF,
or host commands conflicts with normal operation of these
characters. 8-bit data is not recognized when the option

Data

Bits

has been set as 7 Data Bits.

STEP

ACTION

EXAMPLES

1

Desired character/value

‘d’

‘}’

‘D’

Disable Command

Not Used

2

Hex equivalent

0x64

0x7D

0x44

0xFF

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT DISABLE CHARACTER VALUE SETTING

5

Scan Two Characters From

Appendix E, Keypad

‘6’ and ‘4’

‘7’ and ‘D’

‘4’ and ‘4’

‘F’ AND ‘F’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising