Label gone timeout – Datalogic QuickScan Lite QW2100 User Manual

Page 254

Advertising
background image

References

244

QuickScan

TM

Lite QW2100

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new
label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 sec-
onds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a
trigger pull for each label that is read

Follow these instructions to set this feature:

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-

ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

4. Scan the bar code: SELECT LABEL GONE TIMEOUT SETTING.

5. Scan the appropriate three alpha-numeric characters from the keypad in

Appendix E,

Keypad

representing the duration which was determined in the steps above. You will hear

a two-beep indication after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 2

for some examples of how to set this feature.

Table 2. Timeout Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

1800ms (1.8

sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with

leading zeroes)

005

015

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘5’

‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising