16. IR Command Protocol

The Planar UltraRes W Series displays accept commands in the form of IR signals that conform
to the NEC protocol. Each Planar UltraRes W Series remote control has an NEC control code
associated with it. You can use these codes to program a third-

party “universal” remote control

to work with the Planar UltraRes W Series displays. These third-party products usually come
with a computer software application for this purpose. For more information, consult the
documentation provided with the remote control.

The IR control codes have the following characteristics:

• Each code consists of the following:
• A leader pulse (a modulated pulse of 9 ms followed by a non-modulated pulse of 4.5 ms)
• 16 address bits. The default address is 1785 (0x06F9, binary 00000110 11111001)
• 16 data bits: eight (8) bits for the command followed by the logical inverse of the command
• An end pulse (a modulated pulse of 0.56 ms, similar to the modulated pulse in the ‘0’ and

‘1’ bits). The end of the modulated pulse constitutes the end of the data transmission.

• The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle.
• Commands are sent at a maximum rate of 9 Hz.

For example, below is the NEC control code for the ON button of the Planar UltraRes W Series
remote control (assuming the default address is used).

Hex

06

F9

01

FE

Binary

00000110

11111001

00000001

11111110

Function

Address Byte

1

Address Byte

2

Command

Command

(Logical Inverse)

The following example shows the pulse train for this command.