Status Definition of LED Indicators

Normal

RGY - Flash alternately

System self-check

YG - Flash alternately

Warming up

G - Flash slowly

The aircraft is in GPS mode

Warning

Y - Flash slowly

The aircraft is in ATTI mode

Y - Flash quickly

There is no connection between the aircraft

and the remote controller

R - Flash slowly

Low battery warning

R - Flash quickly

Critical low battery warning

R - Normally on

Critical error or IMU error

RY - Flash alternately

Compass error, requiring calibration/magnetic

interference

Compass Calibration

Y - Flash quickly

Prepare to calibrate the compass/The aircraft

is being calibrated

G - Normally on

Calibration succeeded

R - Normally on

Calibration failed

2.1.3 Aircraft Battery

The rechargeable LiPo battery used by EVO Ⅱ Dual 640T V3 features high energy
density and capacity. The battery needs to be charged by a designated charger.

1. Component Description

① Battery Removal Button
② Power Indicator
③ Power Button

Turn on the battery

Make sure that the aircraft is turned off before you install the battery. After you
install the battery, press the power button for 3s. The battery indicator will show the
current battery level.

Turn off the battery

Long press the power button for 3s to turn off the battery. If you have already
installed the battery onto the aircraft, the two LED indicators on the nose and tail of

Advertising