1. Calibration procedure

1. Turn on the aircraft and remote controller, launch the Autel Explorer App, go to
the camera page, and click the Settings button (

). When the calibration starts,

the LED indicator on the back of the aircraft flashes yellow.
2. Hold the aircraft horizontally and rotate it until the LED indicator on the back
displays a solid green light.
3. Hold the aircraft vertically, with the nose pointing downwards, and then rotate it
until the LED indicator on the back glows solid green.
4. Hold the aircraft, with the nose pointing forwards and the side plane downwards,
and then rotate it until the LED indicator on the back glows solid green.

Note

If the calibration fails, the LED indicator on the back of the aircraft blinks red. In
this case, repeat the above steps.