System setup

fig.date-1a.eps

You can set the date and time.

If Project Name is set to Date, the time you specify here is
used to set the date in the project name.
This setting is also used for the date and time shown in the
Main screen.

6 Timecode

Menu item

Parameter

Value

Function

Setup

Mode

OFF

The timecode is not recorded.

INT

The R-4 Pro timecode is used. The timecode
operates normally.

EXT

Uses the timecode sent from the connected
device.

REC-RUN

The R-4 Pro timecode is used. The timecode
only runs during recording.

RTC

The internal clock is used in place of the time-
code.

Frame Rate

24, 25, 29.97, 29.97D, 30, 30D

Selects the frame rate.

Out Select

ON

, OFF

Selects whether to output the timecode to the
timecode connector.

Chase

ON, OFF

Plays the project in the R-4 Pro that matches
the timecode input from the timecode con-
nector.

Set Int TC

MANUAL
(H: M: S: F)

H : 00–23
M : 00–59
S : 00–59
F : 00–23/24/29
(According to the Frame Rate set-
ting)

Sets the start time for the timecode when
Mode is set to INT.

* CURRENT is the current timecode.

JAM EXT
(H: M: S: F)

H : 00–23
M : 00–59
S : 00–59
F : 00–23/24/29
(According to the Frame Rate set-
ting)

When Mode is set to EXT, the start time for
the timecode can be set to match the external
device

* CURRENT is the current timecode.

Set Rec-Run
TC

TARGET

H : 00–23
M : 00–59
S : 00–59
F : 00–23/24/29
(According to the Frame Rate set-
ting)

When Mode is set to REC-RUN, the start time
for the timecode can be set.

7 Date & Time

Year

Month

Date (Weekday)

Time