12 high-speed data output (rx8xxx/swo/ip/data), 14 ip transport stream output (rx8xxx/swo/ip/out), High-speed data output (rx8xxx/swo/ip/data) -11 – Ericsson RX8000 Series User Manual

Page 169: Ip transport stream output (rx8xxx/swo/ip/out) -11

Advertising
background image

Chapter 6

The output bit rate, which is selected by the user, may be constant (by inserting
NULL packets) or variable (plus the increment due to the PSI SI insertion).

6.2.11

Multi-Service Filtering (RX8XXX/SWO/MULTI/SERVFILT)

This option is available for the RX8200, 8310, 8315, 8320 and 8330 Receivers.

This option enables the filtering of services within a Multiple Program Transport
Stream (MPTS) and provides a single CBR MPTS output.

This feature generates a custom MPTS by filtering services from a source MPTS.
This service may be initiated by selecting the Output tab from the web browser then
selecting Filter Mode>MULTI SERVICE. This enables the FILTER column of the
Serviceplus table. From this page, the user is able to select up to 22 services to be
filtered. All components of the selected service will be filtered and presented at the
output MPTS.

The output bit rate, which is selected by the user, may be constant (by inserting
NULL packets) or variable (plus the increment due to the PSI SI insertion).

In Constant mode, if overrate protection is ticked the unit will not clip any services
which ‘over rate’ the selected bit rate. The unit also has the option to insert nulls on
failure. Both of these functions are available from the Output tab of the web control.

6.2.12

High-Speed Data Output (RX8XXX/SWO/IP/DATA)

This option is available for the RX8200, 8310, 8315 and 8330 Receivers.

This option enables MPE-based data de-encapsulation of IP data and requires the
IP TS Output option (RX8XXX/HWO/IP/OUT) to be fitted.

6.2.13

Password Protection of Web Browser (RX8XXX/SWO/PW)

This option is available for the RX8200, 8310, 8315, 8320 and 8330 Receivers.

This option protects the web browser from malicious or accidental changes, only
allowing access via a windows username and password screen.

Note: Default username = username. Default password = password.

6.2.14

IP Transport Stream Output (RX8XXX/SWO/IP/OUT)

This option is only available for the RX8320 ATSC Receiver.

This option enables the IP transport stream output and encapsulation of the
transport stream into multicast. There are two Gigabit Ethernet RJ-45 interfaces
always fitted which are enabled with a feature key.

EN/LZT 790 0005 R1A

6-11

Advertising