B.7 power supply – ac mains input, B.8 cable types, Table b.25 – Ericsson RX8000 Series User Manual

Page 224

Advertising
background image

Annex B

B.7

Power Supply – AC Mains Input

This equipment is fitted with a wide-ranging power supply. It is suitable for supply

voltages of 100-240 V AC -10% +6% at 50/60 Hz nominal.

Table B.25 AC Power Supply Specification

Item Specification

Power distribution system

Type TN ONLY (EN 60950-1 Annex V): Power distribution
system which is directly earthed, the parts of the equipment
required to be earthed being connected by protective
earthing conductors. This equipment must NOT be used
with single-phase three-wire and PE, TT or IT Type Power
distribution systems.

Connection to supply

Pluggable Equipment Type A (EN 60950-1 para 1.2.5):
Equipment which is intended for connection to the building
power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance Coupler or both.
Correct mains polarity must always be observed. Do not
use reversible plugs with this equipment.

Class of equipment

Class I Equipment (EN 60950-1 para 1.2.4): electric shock
protection by basic insulation and protective earth.

Rated voltage

100-240 V AC (single phase)

Rated frequency

50/60 Hz

Voltage selection

Wide-ranging

Rated current

RX83xx: 1 A (100-240 V AC range)
RX82xx: 1.5 A (100-240 V AC range)

Input connector

CEE 22/IEC 3-pin male receptacle

Fuse

Fuse in live conductor in power input filter at rear of unit. Do
not use reversible plugs with this equipment.

Fuse type

Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5

Fuse current rating

All RX8000 models: 2 A 250 V T HBC

Power consumption

45 W typical (NO options fitted)
60 W maximum

B.8

Cable Types

The signal cable types (or similar) in Table B.26 are those recommended by
Ericsson in order to maintain product EMC compliance.

EN/LZT 790 0005 R1A

B-20

Advertising