Output interface pcb mounted in module 1, M1 m2 m3, Output interface pcb mounted in module 2 – Emerson 7400 User Manual

Page 54

Advertising
background image

45

Series 7400 Single Phase 1+N UPS

MAINS OK

(BYPASS)

RECTIFIER

ACTIVE

BATTERY

OK

END OF

DISCHARGE

INVERTER

OK

SYNCHRO

OK

LOAD ON

UPS

LOAD ON

BYPASS

OVER

TEMPERATURE

OVERLOAD

MAINT. BYP.

ENABLED

STATIC BYPASS

ISOLATOR CLOSED

OUTPUT SWITCH

CLOSED

SYNCHRO INHIBIT

INVERTER ON/OFF

OUTPUT INTERFACE PCB

MOUNTED IN MODULE 1

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

M1

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

M2

1
2
3
4
5
6
7
8
9

10
11
12
13

M3

RELAY
RELAY

M1

M2

M3

RELAY
RELAY

1

2

3

4

5

6

7

8

9

10

N

L

1

2

3

4

5

6

MIMIC STATUS LED –MAINS (BYPASS) OK

MIMIC STATUS LED –RECTIFIER ACTIVE

MIMIC STATUS LED –BATT. BREAKER OK

MIMIC STATUS LED –INVERTER OK

STATUS LED

LOAD ON UPS

STATUS LED

LOAD ON BYP.

ALARM SIGNAL LED

–MAINS (BYPASS) VOLTAGE NOT OK

ALARM SIGNAL LED

RECTIFIER 2 NOT ACTIVE

ALARM SIGNAL LED

BATTERY BREAKER 2 NOT OK

ALARM SIGNAL LED

PREALARM END OF DISCHARGE

ALARM SIGNAL LED

INVERTER 2 NOT OK

ALARM SIGNAL LED

SYNCHRO NOT OK

ALARM SIGNAL LED

LOAD ON MAINTENANCE BYPASS

24V

TERMINALS OF

INTERFACE PCB

TERMINALS OF

INTERFACE PCB

TERMINALS OF RAM

RM3

RM2

RM1

MODULE 1 & 2

M2

M1

M2

M1

M1

M1

M1

M2

M2

M3

M1

M1

M1

M1

M1

M1

-8

-2

-5

-14

-5

-8

-11

-1

-14

-2-4

-4

-13

-13

-7

-7

MODULE 1

MODULE 2

MODULE 1

MODULE 2

MODULE 1

MODULE 2

M2

M1

M2

M1

M1

M1

M1

M2

M2

M3

M1

M1

M1

M1

M1

M1

-8

-2

-5

-14

-5

-8

-11

-1

-14

-2-4

-4

-13

-13

-7

-7

MODULE 1

MODULE 2

MODULE 1

MODULE 2

MODULE 1

MODULE 2

TERMINAL CONNECTION ARE GOING TO

TEST

RESET

+ 24 V

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

10
11
12
13

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

NOTES:

1.

Short terminal with the help of suitable wire.

2.

Note that if this supply is not available, RAM will not
function

3.

USF, 24 core, 1.5mm, multistrand cable for
interconnection between RAM and Output interface

4.

Status of contacts is shown when relay is ‘Off’.
Relay switches ‘On’ when signal is received as per
the description

MAINS OK

(BYPASS)
RECTIFIER

ACTIVE
BATTERY

OK
END OF

DISCHARGE
INVERTER

OK

SYNCHRO

OK
LOAD ON

UPS
LOAD ON

BYPASS

OVER

TEMPERATURE
OVERLOAD

MAINT. BYP.

ENABLED

STATIC BYPASS

ISOLATOR CLOSED
OUTPUT SWITCH

CLOSED
SYNCHRO INHIBIT

INVERTER ON/OFF

ALARM SIGNAL LED

–MAINS (BYPASS) VOLTAGE NOT OK

ALARM SIGNAL LED

RECTIFIER 1 NOT ACTIVE

ALARM SIGNAL LED

BATTERY BREAKER 1 NOT OK

ALARM SIGNAL LED

PREALARM END OF DISCHARGE

ALARM SIGNAL LED

INVERTER 1 NOT OK

ALARM SIGNAL LED

SYNCHRO NOT OK

ALARM SIGNAL LED

LOAD ON MAINTENANCE BYPASS

24V

STATUS LED

LOAD ON UPS

STATUS LED

LOAD ON

BYPASS

MIMIC STATUS LED

– INVERTER OK

OUTPUT INTERFACE PCB

MOUNTED IN MODULE 2

230V AC Supply

Figure 27: Interconnection d iagram for single module RAM and UPS Interface PCB 1+1 System