Model OFE/OFG/OEA/OGA-341, 342





2-1. INTRODUCTION

This section provides procedures for the check out and

replacement of the various parts used within the fryer. Before

replacing any parts refer to the Troubleshooting Section. It will aid

you in determining the cause of the malfunction.


2-2. MAINTENANCE HINTS

1. You may need to use a multimeter to check the electric

components.

2. When the manual refers to the circuit being closed, the

multimeter should read zero unless otherwise noted.


3. When the manual refers to the circuit being open, the

multimeter

will

read

infinity.


2-3. HIGH TEMPERATURE
LIMIT CONTROL

This high temperature control is a safety, manual reset control,

(Gas Units)

which senses the temperature of the shortening. If the short-

ening

temperature

exceeds

425

°F (218°C), this switch opens

and shuts off heat to the frypot. When the temperature of the

shortening drops to a safe operation limit, the control must be

manually reset by pressing the red reset button. The red reset

button is located under the control panel, in the front of the fryer.

(Figure 2-1). This allows heat to be supplied to the frypot.


Before replacing a high temperature limit control, check to see

that

its

circuit

is

closed.

Figure 2-1

The shortening temperature must be below 380

°F (193°C)

to accurately perform this check.

Checkout


To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


1.

Remove

the

control

panel.

Figure

2-2.

Figure

2-2




1003

2-1

SECTION 2. MAINTENANCE