2-20. HIGH TEMPERATURE
LIMIT

CONTROL

(ELECTRIC)

(Continued)

4. Straighten the capillary tube, and pull capillary tube through
the hole in the element hinge, from the rear of the fryer.



5. Remove the defective control from the fryer.




Figure 2-69

6. Straighten the capillary tube on the new high limit, and thread

the capillary tube through the hole in the element hinge.

Figure 2-69.

7. Reattach the capillary to the brackets on the upper and lower

parts of the elements.


DO NOT crimp or kink the capillary tube during installation.

Also, keep capillary tube behind element to protect from

damage from the basket or during cleaning. Damage to the

capillary tube reduces the life of the high limit, or causes the

high

limit

to

fail.


8. Connect wires to new high limit body and fasten to bracket,

using the two screws removed in the checkout part of this

section.

Make sure red reset button of high limit lines up with the

plunger that inserts into the element hinge.


To avoid electrical shock or other injury, run the capillary

line under and away from all electrical power wires and

terminals. The tube must never be in such a position

where it could accidentally touch the electrical power

terminals


9. Re-install the rear cover and unit is now ready for use.