2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should

REPLACEMENT

“open”, cutting off the pilot flame. This will prevent the fryer

from heating while shortening is being drained from the frypot.

1. Remove electrical power supplied to the unit.





To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


2. The following check should be made to determine if the drain

microswitch

is

defective.


a. Remove the two screws and nuts securing the microswitch

Figure 2-32

to the drain rod valve bracket, and remove microswitch.

Figure

2-32.


b. Remove wires from the switch. Figure 2-33.


c. Check for continuity across the two outside terminals of the

drain switch. If the circuit is open, the drain switch is

defective. The circuit opens by pressing on the actuator of

the

microswitch.


3. If defective, replace switch in reverse order.

Figure 2-33


2-14. FILTER SWITCH
REPLACEMENT

1. Remove electrical power supplied to the unit.





To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


2. Open the door (left door on 2 well units), and remove the 2

Figure 2-34

screws securing the switch box cover. Figure 2-34.