Model OFE/OFG/OEA/OGA-341, 342



2-9. IGNITION MODULE

During normal operation, the ignition modules send 24 volts to the

ignitors and gas valve. If a module does not sense a pilot flame,

the module starts the ignition process again. But, if a pilot light

goes out for longer that 10 seconds, or it goes out 3 times within 10

seconds, the module keeps the 24 volts from reaching the gas

valve.

The

burners

shut

down.


1. Remove electrical power supplied to the unit.





To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.



Figure

2-23

2. Remove the control panel and heat shield from control area.

Figure

2-23.





3. Using a 3/8 inch socket, remove the two nuts securing the

module.

Figure

2-24.




Figure 2-24


4. Label and remove the wires at module. Figure 2-25.





5.

Install

new

module

in

reverse

order.



Figure

2-25







1003