Henny Penny 342 User Manual

Page 17

Advertising
background image

Model OFE/OFG/OEA/OGA-341, 342



2-16. BLOWER MOTOR
REPLACEMENT
(Continued)




8. Using 3/8 inch nut driver, remove nuts securing blower to the

unit. Figure 2-48. Pull blower from unit.





Figure 2-48

9. Install new blower in reverse order.


2-17. HEATING ELEMENTS

(ELECTRIC)

Heating elements are available for 208 and 230 voltage. Check

data

plate

to

determine

correct

voltage.


Checkout

If the shortening temperature recovery is very slow or at a slower

rate than required, this may indicate defective heating element(s).

An ohmmeter quickly indicates if the elements are shorted or open.


1. Remove electrical power supplied to the frypot to be checked



To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other control on 2-frypot

Figure 2-49

units will have power.



2.

Remove

rear

cover.

Figure

2-49.


3. Using a flat-head screwdriver, remove the appropriate wires

from the terminal blocks. Figure 2-50.


Figure

2-50



106

2-17

Advertising