2-7. TEMPERATURE PROBE 4. Using a ½ inch wrench, remove the nut on the compression
REPLACEMENT

fitting. Figure 2-18.

(ELECTRIC) (Continued)

5. Remove the probe from the frypot, and disconnect probe.



6. Place the nut and new ferrule on the new probe and insert the

probe into the compression fitting until it extends one (1) inch

(2.54cm)

into

the

frypot.


7. Reconnect new probe onto wires, replace rear cover, and fryer

Figure 2-18

is now ready for use.

2-8. FLAME SENSOR/

The Henny Penny open fryer (gas) has electronic spark ignition

PILOT / IGNITOR

that lights a standing pilot. The gap between the spark electrode

ASSEMBLY (GAS)

and the pilot hood should be1/8 of an inch (3.18 mm). The

flame sensor recognizes the pilot flame and allows gas to continue

to the pilot. The flame sensor must send a minimum of two (2)

micro amps to the ignition module. The pilot flame should be split

in two by the flame sensor, causing the flame sensor to be bright

red in color.


1. Remove electrical power supplied to the unit.



To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE,

BEFORE

STARTING

THIS

PROCEDURE, MOVE THE MAIN POWER SWITCH

TO

THE

OFF

POSITION. DISCONNECT THE MAIN

CIRCUIT BREAKERS AT THE CIRCUIT BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE

EXPLOSION

COULD

RESULT.