Model OFE/OFG/OEA/OGA-341, 342



2-14. FILTER

SWITCH

3. Label and remove the wires from the switch. With test

REPLACEMENT

instrument check across the terminals of the switch. With the

(Continued)

switch in the on position, the circuit should be closed. With the

switch in the off position, the circuit should be open. If the

switch is defective, replace by continuing with this

procedure. Figure 2-35.








Figure 2-35


4. With wires removed from the switch, push in on tabs on the

switch and remove switch from front of switch box cover.

Figure

2-36.



5. Push new switch into panel and reconnect wires.



Figure

2-36


2-15. GAS CONTROL VALVE
The gas valve assembly controls the flow of gas to the pilot and the

REPLACEMENT

main burner. The valve has two 24-volt coils, which are regulated

by the P and M terminals on the valve. The C terminal is the

common terminal. For gas flow to the pilot, 24 VAC must be

present between the P and C terminals. For gas flow to the main

burner, 24 VAC must be present between the M and C terminals.


TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE,

BEFORE

STARTING

THIS

PROCEDURE, MOVE THE MAIN POWER SWITCH

TO

THE

OFF

POSITION. DISCONNECT THE MAIN

CIRCUIT BREAKERS AT THE CIRCUIT BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE

EXPLOSION

COULD

RESULT.