Henny Penny 342 User Manual

Page 5

Advertising
background image

Model OFE/OFG/OEA/OGA-341, 342



2-5. POWER SWITCH (Continued)

4. With control panel removed, and the wires off the switch, push

in on tabs on the switch to remove from panel. Figure 2-12.


5. Replace with new switch, and reconnect wires to switch.


6.

Replace

the

control

panel.


Figure 2-12

2-6. TEMPERATURE PROBE

The temperature probe relays the actual shortening temperature

REPLACEMENT (Gas)

to the control board. If it becomes disabled, “E06” shows in the

display. Also, if the shortening temperature is out of calibration

more than 10

°F or C°, the probe should be replaced. An Ohm check

can be performed also. See chart below.















1. Remove electrical power supplied to the fryer.



Figure 2-13


To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


2. Drain the shortening from the frypot.


3. Remove the control panel and heat shield from control area.

Figure

2-13.


4. Using a ½ inch wrench, remove the nut on the compression

Figure 2-14

fitting. Figure 2-14.


806

2-5