2-20. HIGH TEMPERATURE

LIMIT

CONTROL

(ELECTRIC)
(Continued)

4. Pull back cardboard cover and remove the two electrical wires

from the high temperature limit control. Figure 2-66.







Figure 2-66

5. Manually reset the control, then check for continuity between

the two terminals after resetting the control. If the circuit is

open, replace the control, then continue with this procedure.

(If the circuit is closed, the high limit is not defective. Re-

connect the two electrical wires.)


Replacement

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other control on 2-frypot

units

will

have

power.


1. Drain the shortening from the frypot.


Figure

2-67

2. Remove capillary from brackets on upper part of element.

Figure

2-67.




3. Remove capillary bulb from bulb holder inside the frypot.





Figure

2-68

2-24

1003