Model OFE/OFG/OEA/OGA-341, 342



2-3. HIGH TEMPERATURE

LIMIT CONTROL
(Gas Units) (Continued)

Replacement

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


1. If the tube is broken or cracked, the control opens, shutting

off electrical power to the heat circuit. The control cannot be

reset, and it continuously clicks when pushed.


2. Drain the shortening from the frypot and discard. A substance

from the tube could contaminate the shortening.


Figure 2-6

3. Remove the control panel.


4. Using a 5/16” wrench, loosen small inside screw nut on

capillary

tube.

Figure

2-6.



5. Using a 11/16” crows-foot, remove the larger nut securing the

capillary tube to the pot. Figure 2-7.



6. Remove the two screws securing the high limit guard and

Figure 2-7

remove guard. Figure 2-8




7. Straighten the capillary tube inside the frypot, and pull the

capillary tube through the frypot, from behind the control

panel. Remove the defective high limit from the control panel

area.


8. Replace new high limit in reverse order.


Figure 2-8


To avoid electrical shock or other injury, run the

capillary line under and away from all electrical power

wires and terminals. The tube must never be in such a

position where it could accidentally touch the electrical

power

terminals.