Henny Penny 342 User Manual

Page 20

Advertising
background image

Model OFE/OFG/OEA/OGA-341, 342



2-18. HEATING
CONTACTORS

(ELECTRIC)
(Continued)

To avoid electrical shock, make connections before

applying power, take reading, and remove power before

removing meter leads. The following checks are

performed with the wall circuit breaker closed and the

main power switch in the ON position.

1. Re-apply power to unit and turn power switch to ON.


2. Using illustrations from previous page, check voltage as

follows:


Test Points

Results

Heat

Contactor

From terminal 34 to 35

The voltage should read

From terminal 35 to 36

the same at each terminal

From

terminal

34

to

36


Test Points

Primary

Contactor

From terminal 27 to 28

It should correspond to the

From terminal 28 to 29

voltage stated on the data

From

terminal

27

to

29 plate.

Replacement

If neither contactor is defective it must be replaced as follows:

(Heat

Contactor)

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle, to the frypot

to be worked on. Be aware the other control on 2-frypot

units will have power.





1. Remove only the wires directly connected to the contactor

Figure 2-54

being replaced. Label the wires for replacement. Figure 2-54.