Model OFE/OFG/OEA/OGA-341, 342



1-3. HIGH TEMPERATURE

2. Using a Phillip’s head screwdriver, remove the screws securing

LIMIT CONTROL

the inner heat shield and remove from unit. Figure 2-3.

(Gas Units) (Continued)









Figure

2-3

3. Remove the screw securing the high limit bracket to the frame

and remove the high limit and bracket from unit. Figure 2-4.








Figure

2-4

4. Remove the two screws securing the high limit to the bracket

and remove the high limit from bracket.




5. Remove the two electrical wires from the high temperature

limit

control.

Figure

2-5.



Figure 2-5

6. Manually reset the control, then check for continuity between

the two terminals after resetting the control. If the circuit is

open, replace the control, then continue with this procedure.

(If the circuit is closed, the high limit is not defective. Re-

connect the two electrical wires.)