Model OFE/OFG/OEA/OGA-341, 342



2-16. BLOWER MOTOR

REPLACEMENT

(Continued)


3. Remove the wire cover from the blower motor housing.

Figure

2-44.




Figure 2-44

4. Remove wire nuts connecting blower motor wires to wires in

conduit.

Figure

2-45.





Figure

2-45


5. Loosen conduit from blower motor. Figure 2-46.








Figure

2-46


7. Remove screws connecting flue to blower. Figure 2-47.






Figure

2-47