Malfunctions, causes, remedy

Malfunction

Cause

Remedy

Tractive force too low

Fault in the feed pressure or high
pressure system

Check the feed pressure of hydraulic system

Check the high pressure hydraulic system

Check for leakage at variable pump and
variable motor

Check the variable pump controls and
proportional solenoids

Check the maximum current at
proportional solenoids

Eliminate determined faults

No forward and reverse travel

Direction switch in neutral position

Machine was started with direction of
travel preselected

Electronics without electrical power

Traction electronics defective

Electrical connection to the variable
pump is interrupted

Put the direction switch to the desired
direction of travel

Put direction switch in neutral position and
preselect desired direction of travel

Check the fuses
Check the electrical connection

Read out fault with BB3 or Bodem and
eliminate fault

Make a connection