Malfunctions, causes, remedy

Malfunction

Cause

Remedy

Joystick inoperative

Joystick locked

Buttons defective

Release with Opus or PC software

Determine fault with Opus, submit the
joystick for repair, or replace it

Membrane keyboard inoperative

Mechanically or electrically
defective

Determine fault with Opus or PC
software, replace membrane keyboard
and/or related printed circuit board

Simultaneous failure of many joystick
and membrane keyboard functions

Power supply interrupted
(3 separate positive cables, pin 05,
23, 34)

Determine and eliminate the defect
(cable breakage, contact problems in
the plug) Attention: Although voltage is
applied in the quiescent state, power
failure can result during operation

Functions operate too slowly or too
fast

Flow rate limiting out of adjustment

Current value for a certain channel
too low

Readjust with hash (#) key and joystick
or Opus or PC software

Adjust from 800 to 1900 mA in
"Channels" area with Opus or PC
software

4th control level on joystick
"malfunctioning"

Special function activated with
asterisk (*) key

Push the asterisk (*) key again

Joystick or membrane keyboard not
functioning

Bus cable is defective (Opus does
not indicate a connection)

Make a connection or replace the
cable