Operating Instructions

153 146

211

C 9.92

Annual maintenance

Bild_C992H_091

2

3

1

Before doing work on the electrical equipment, cut off the
power with the battery isolating switch (3).

-

The switch must be in the vertical position and the
toggle removed.

-

Disconnect the battery ground lead (2).

-

Disconnect the battery positive lead (1).

CAUTION
Do not place any metal parts on the battery
poles. Risk of short circuit!

-

Coat the battery poles and battery terminals lightly
with pole grease.

-

Charge the battery and top up the electrolyte with
distilled water.

Lubricating the universal joints

-

Refer to page 204 of maintenance every 1000 service
hours.