Malfunctions, causes, remedy

Malfunction

Cause

Remedy

Many malfunctions

Some parameters out of adjustment

Upload "standard values" with Opus or
PC software

Keys respond too slowly

Set to "slow"

Can be set to "fast" with Opus or PC
software

Keys "stay put” instead of "returning"

Out of adjustment

Adjust with Opus or PC software

Hydraulic accumulator inoperative

Switched off

Electronic pressure sensor defective

Desired value too low

Function switched to rear lift

Turn on with membrane keyboard

Replace

Change at electronic pressure sensor

Change to "front" with Opus

Hydraulic accumulator pulsating
strongly

Desired pressure value and
hysteresis (sluggishness) too low or
too high

Weight of attachment is too low

Hydraulic accumulator defective, no
resilience determinable

Change values at electronic pressure
sensor

Switch the hydraulic accumulator off

Renew the hydraulic accumulator

Way valve leaking

Foreign particles in the seat valve

Remove, clean or replace the valve
cartridge